The MAC address specific to each controller is described on the seal attached to the main board
(remove the side panel which is on the left side of the unit). For Windows NT/2000/XP, the
MAC address can be obtained by using the following command:
ipconfig/all
CAUTION:
If connection is made directly from an outdoor, overhead LAN cable, the connected
equipment may be damaged by lightning. When connecting to such a cable, the
connection should be routed through a device to counter the surge; otherwise, do not
use the connection.

Power Supply Unit

Input Specification
Input voltage:
Frequency (rating):
Input current:
Outlet current
Protection Circuit/Unit
When the protection circuit is activated, it automatically shuts off the power. If recovery is
possible, turn off the main power switch, wait for more than 2 minutes, and then turn on the
main power switch.
Short-circuit protection:
Shuts down the system when the output terminal (output power supply) is short-circuited.
Recovery is possible.
Over-voltage protection:
Protection circuit to prevent the output terminals from exceeding the rated voltage.
Recovery is possible.
Overheating protection:
Shuts down the system when excessive heat is detected in some element within the power
supply unit. Recovery is possible.
Input power fuse:
Shuts down the system when the input current exceeds the specified value. Trouble within
the power supply unit is possible. If the fuse has blown, the whole power supply unit should
be replaced. Recovery is impossible.
Rev. C
100 to 240 V AC (± 10%)
50/60 Hz (± 3 Hz)
6.0 A (100 V) to 4.0 A (240 V)
(except the power for AC outlet).
3A(rating)
The output of the AC outlet is interlocking with the power
on/off control in the system.