Software Configuration - Epson IR-320 Technical Reference Manual

Hide thumbs Also See for IR-320:
Table of Contents

Advertisement

Layer Function Specifications
Number of Layers
Number of Defined Data
Default Layer
Layer Switching Method
Change Layer Key
Notes:
The layer returns to Layer 0 when the change layer key is released after being pressed. In the case of
changing a layer other than 0 using the software, as the same method, it returns to Layer 0 without
returning the layer set with the software.
In case multiple change layer keys are pressed, when any change layer keys are released, the layer
returned 0 not to change the layer is pressing. Under this case, when the layer is changed using the
software, it returned Layer 0 at the same time of other change layer keys are released.
In the previous 28-key definition utility and 84-key definition key, keys are defined with respect to
Layer 0 (when starting), so if a layer other than Layer 0 is set, keys are not input.
The KeyLock key can be operated without relation to the layer function.
If the layer function is not being used, use the layer 28-key definition utility and leave the change layer
keys unset.

Software Configuration

Layer 28-key Definition Utility
Layer 28-key Auto Definition Utility for Windows : PKLDL32.EXE
Layer 28-key Auto Definition Utility for MS-DOS : PKLDL.EXE
Layer Switching and Reading Library (Windows edition)
Note:
There is no layer version of the 28-key definition utility for DOS.
4-26 Utilities
: 4 Layers (Layers No. 0 - 3)
: Maximum 63 data items (per key, per layer)
: Layer 0 (when starting)
: Shift key type
: It is possible to set a single change layer key for each layer (a total of 3 keys).
If multiple change layer keys are pressed at the same time, the change layer key
that was pressed last becomes the enabled key.
:28KYCFGL.EXE
Rev. C