Interface

Serial Connectors

The IR-320 has four NS16550-compatible serial ports (COM1, COM2, COM5, COM6). It has four
outside connectors, however, COM5 and COM6 cannot be used by default. Assign COM5 and
COM6 to interrupts not in use.
Assignment of serial connector signals
No.
Signal name
1
DCD/power supply (*) I/—
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
(*) Pin 1 can be set for +5 V output and +12 V output with the jumper settings (JP7 to JP18) on the main board.
Rev. C
1
6
I/O
Description
Carrier detection signal or power supply output
I
Received data signal
O
Transmission data signal
O
Terminal ready signal
Ground
I
Data set ready signal
O
Transmission request signal
I
Transmission data cleared signal
I
Ring signal