Note:
To execute this utility, be sure to exit Windows, and reboot the system from MS-DOS beforehand. This
utility cannot be executed from the DOS box.
To use the MSR unit, execute this utility or the Keyboard Firmware Setting utility for Windows, and set
the track to be read. To make the JIS2 type card readable, execute the following command:
PKMODE2 MSR=12J
Commands
Run the utility by typing the command in the following format:
PKMODE2.EXE[MSR1|MSR3|MSR] [US|JP|FR|GR|SP] [CMDOFF|CMDON]
[TK0SS=string] [TK0ES=string] [TK1SS=string] [TK1ES=string]
[TK2SS=string] [TK2ES=string] [TK3SS=string] [TK3ES=string]
[TKJSS=string] [TKJES=string] [BEEP=ON|BEEP=OFF] [MSR=m...]
[KEYTBL=pathname] [/TRACE] [/TRON] [/TROFF]
[/VAL=xxh,yyh] [/PARA[zzh]]
Description of parameters:
MSR1:
MSR3:
MSR:
US:
JP:
FR:
GR:
SP:
CMDOFF:
CMDON:
4-54 Utilities
Prohibits decoding for Track 3. Set when the DM-MR111-012 is
mounted.
Prohibits decoding for Track 1. Set when the DM-MR111-013 is
mounted.
Sets the MSR unit decode to enable the 3-track decodes for Track 1,
Track 2, and Track 3. Sets the DM-MR123 when it is selected.
Responds with the MSR data in the scan code of the English 101-key
keyboard (default value).
Responds with the MSR data in the scan decode of the Japanese 106-key
keyboard.
Responds with the MSR data in the scan decode of the French 106-key
keyboard.
Responds with the MSR data in the scan decode of the German 106-key
keyboard.
Responds with the MSR data in the scan decode of the Spanish 106-key
keyboard. This country setting is effective also for the default key setting
of the 28-key keyboard. The specification of FR/GR/SP cannot be used
for the IR-300.
Outputs all commands to the external K/B, neglecting the K/B interface
command. Sets such things as the programming of the POS keyboard
connected to the external K/B before executing them. According to this
setting, the command cannot be executed until it is reset or the power is
turned off. The CMDOFF is cancelled, however, when it is reset or the
power to the main body is turned off, and the CMDON status is
resumed.
Accepts the command of the K/B interface (default value).