Epson IR-320 Technical Reference Manual page 279

Hide thumbs Also See for IR-320:
Table of Contents

Advertisement

2) IDE Primary master, IDE primary slave, IDE secondary master, IDE secondary slave
Item
IDE Primary Master /
Primary Slave /
Secondary Master /
Secondary Slave
Access Mode
Capacity
Cylinder
Head
Prcomp
Rev.C
Options
Notice
None
Set the detection method for the connection device.
Auto
None:
Manual
Auto:
Manual: The information set by the user is applied.
CHS
Set the access Method to the connected device. Note that when the
LBA
device detection method is set as "None" it cannot be changed.
Large
CHS:
Auto
LBA:
Large:
Auto:
-----
This item indicates the memory capacity for the connection device.
The following differences occur, depending on the device detection
method used.
Auto:
Manual: The value calculated according to information specified by
-----
This item indicates the number of cylinders for the connection device.
The following differences occur, depending on the device detection
method used.
Auto:
Manual: The user can set the value within a range of 0-65,535 only when
-----
This item indicates the number of heads for the connection device. The
following differences occur, depending on the device detection
method used.
Auto:
Manual: The user can set the value within a range of 0-255 only when
-----
This item indicates the number of write compensation cylinders for the
connection device. The following differences will occur, depending on
the device detection method used.
Auto:
Manual: The user can set the value within a range of 0-65,535 only when
The connection detection is not executed. It is treated as
disconnected software
Auto detection is executed. The information held by the
device is automatically applied.
Access for the device is shortened with "Cylinder Head Sector
(Addressing) "having 0 to 1023 cylinders, 0 to 15 heads and 0
to 63 sectors.
Shortened with the Logical Block Addressing Method, the
entire memory area is divided into access units and those serial
numbers are used for accessing.
This is the access method for extended CHS. When the number
of CHS cylinders exceeds the normal amount of 1024 cylinders,
the address is not accessible so the CHS is extended.
BIOS determines the optimum method based on the
information obtained by the device. The LBA method is
normally used.
The value calculated according to information obtained by
the device is displayed.
the user is displayed.
The value obtained by the device is displayed.
the access method is set as "CHS".
The value obtained by the device is displayed.
the access method is set as "CHS".
The value obtained by the device is displayed.
the access method is set as "CHS". (When connecting a
device for which there is no particular value specified, a
maximum value of 65,535 is specified)
IR-320 Technical Reference Manual
5-19 BIOS Functions

Advertisement

Table of Contents
loading

Table of Contents