6. Periodical check
6.2
Maintenance items
NOTE
• To determine when the main body and option maintenance items need cleaning or
replacing, use the jig software and select [Service Mode] → [Counter] → [Life] in
the software to check the relevant life counter values.
6.2.1
Main body
A. Parts to be replaced by users (CRU)
No
Class
1
Imaging unit Y,M,C
2
Imaging unit K
3
Processing
Toner cartridge Y,M,C
sections
4
Toner cartridge K
5
Electrostatic charger wire
Image transfer
6
Waste toner box
section
*1: The parts can be replaced either by user or service engineer.
For details of setting, see [Unit Replacement] on "Adjustment/Setting."
See P.237
*2: A waste toner full condition is detected with detecting the actual waste toner emissions.
B. Periodical parts replacement/cleaning 1 (per 150,000-print)
No.
Class
Paper feed and image
1
conditions
Overall
2
Appearance
Image transfer entrance
3
guide
Image transfer
4
IDC/registration sensor
section
5
Transfer belt unit
6
Transfer roller unit
Processing
7
Ozone filter
sections
12
Parts to be replaced
When toner cartridge K
Parts to be replaced
Field Service Ver. 1.0 Oct. 2007
Cycle
Clean Replace
90,000
120,000
20,000
26,000
is replaced
(50,000)
Qt.
Check Clean Replace
⎯
●
⎯
●
●
⎯
●
⎯
●
●
1
●
1
●
1
Descrip-
tions
●
*1
●
*1
●
*1
●
*1
●
●
*1,2
Lubri-
Descrip-
cation
tions