15.12 Settings In The Enhanced Security; Admin. Password; Service Password; Data Backup - Konica Minolta bizhub C353P Service Manual

Hide thumbs Also See for bizhub C353P:
Table of Contents

Advertisement

15. Service Mode

15.12 Settings in the Enhanced Security

15.12.1

Admin. Password

Functions
• To set and change the administrator password.
Use
• Use to change the administrator password.
• Use this function when the administrator forget the administrator password because
a new password can be set without entering the current administrator password with
this.
Setting/
• Enter the administrator password (8 digits) using the
Procedure
• The initial setting is "12345678."
New Password
Reenter Password : Enter the new administrator password again.
NOTE
• When the following setting leads to the Password Rules [ON], the password
with the same letters, the password which is same as the previous one and the
password of less than eight digits cannot be changed.
[Admin. Settings] → [Security Settings]
15.12.2

Service Password

Functions
• To set and change the service password.
Use
• Use to change the service password.
Setting/
• Enter the service password (8 digits) using the
Procedure
• The initial setting is "92729272."
Current Password : Enter the currently using service password.
New Password
Reenter Password : Enter the new service password again.
NOTE
• When the following setting leads to the Password Rules [ON], the password
with the same letters as well as the password which is same as the previous
one cannot be changed.
[Admin. Settings] → [Security Settings]
• NEVER forget the service password. When forgetting the service password,
call responsible person of KMBT.
15.12.3

Data Backup

Functions
• To backup NVRAM data in the main body to the flash memory.
Use
• To backup current data in order to prevent data in NVRAM from being erased unex-
pectedly.
• To backup data manually. It usually makes backup every hour automatically.
• Backup data can be restored by following the specified procedure when the trouble
(CD3XX) occurred.
Refer to "Troubleshooting" for details on restoration procedure.
See P.455
1. Select [Data Backup] → [Start]
Setting/
Procedure
2. Press the Menu/Select to start making a backup.
3. Check the message [Completed. Please turn power OFF and ON.], and turn power
switch OFF. Wait for ten seconds or more and turn power switch back ON.
272
: Enter the new administrator password.
: Enter the new service password.
Field Service Ver. 1.0 Oct. 2007