Field Service Ver. 1.0 Oct. 2007
9.3.3
C0210: LCT lift failure
Lift-up upper sensor (PS4)
Lift-up lower sensor (PS13)
Elevator motor pulse sensor (PS10)
Lower over run sensor (PS7)
Step
Check the sensor connectors for proper
1
connection, and correct as necessary.
2
PS4 I/O check, sensor check
3
PS13 I/O check, sensor check
4
PS10 I/O check, sensor check
5
PS7 I/O check, sensor check
6
PCCB replacement
9.3.4
C0212: LCT lock release failure
Tray lock solenoid (SD1)
Step
Check the SD1 connector for proper con-
1
nection, and correct as necessary.
2
SD1 operation check
3
PCCB replacement
Relevant electrical parts
Action
Relevant electrical parts
Action
PC control board (PCCB)
WIRING DIAGRAM
Control signal
—
PCCB PJ5PCCB-12 (ON)
REYB PJ2REYB<A>-9 (ON)
REYB PJ2REYB<A>-5 (ON)
REYB PJ2REYB<A>-2 (ON)
—
PC control board (PCCB)
WIRING DIAGRAM
Control signal
—
PCCB PJ7PCCB-4 (ON)
—
9. Trouble code
Location
(Electrical
components)
—
PC-405 F-8
PC-405 K-3
PC-405 K-5
PC-405 K-6
—
Location
(Electrical
components)
—
PC-405 F-10
—