Ccd Check; Memory/Hdd Adj - Konica Minolta bizhub C353P Service Manual

Hide thumbs Also See for bizhub C353P:
Table of Contents

Advertisement

Field Service Ver. 1.0 Oct. 2007
16.13.8

CCD Check

Functions
• To display the D/A value of CCD clamp/gain for R, G, and B.
Use
• Used for troubleshooting for the CCD sensor.
Setting/
• Use the following guidelines on the correct range of values.
Procedure
CLAMP: The difference between the max. and min. output values should be
GAIN : The difference from the CLAMP values (R, B) should be within (90 for R
16.13.9

Memory/HDD Adj.

A. Memory Check
Functions
• To check correspondence of data written to and that read from memory through
write/read check.
Rough Check
• A check is made to see if the image data reading and writing are correctly made in a
very limited area.
• The progress of the check sequence is displayed in percentage.
Detail Check
• A check is made to see if the image data reading and writing are correctly made at
the addresses and buses in all areas.
• The progress of the check sequence is displayed in percentage.
Use
• If the printed image is faulty.
Adjustment
1. Call the Service Mode to the screen.
2. Click these keys in this order: [State Confirmation] → [Memory / HDD Adj.] → [Mem-
Procedure
ory Check].
3. Select the desired type of check, either [Rough Check] or [Detail Check].
4. Click the Start key to start the check procedure.
5. When the check procedure is completed, the results are shown on the screen.
If the check results are NG, check the memory for connection or replace the memory
with a new one.
✽ Click the Stop key to interrupt the check sequence.
B. Compress / Decompression Check
Functions
• To check whether compression and decompression are carried out properly.
Use
• If the printed image is faulty.
Adjustment
1. Call the Service Mode to the screen.
2. Click these keys in this order: [State Confirmation] → [Memory / HDD Adj.] → [Com-
Procedure
press / Decompression Check].
3. Clicking the Start key will automatically start to complete a compression/decompres-
sion check sequence.
4. The check result will be displayed.
within ±100.
and B. The difference from the CLAMP value (G) should be within ±50
for G. The difference between each pair of RO and RE, GO and GE, and
BO and BE should be within 30.