16. Jig Software
16.17.7

IU Life Stop Setting

Functions
• To select whether or not to stop a print cycle when the IU reaches its service life.
Use
• Use to select not to stop the print cycle when the IU reaches its service life.
Setting/
The default setting is Stop.
Procedure
16.17.8

NVRAM Data Backup

Functions
• To backup NVRAM data in the main body to the flash memory.
Use
• To backup current data in order to prevent data in NVRAM from being erased unex-
pectedly.
• To backup data manually. It usually makes backup every hour automatically.
• Backup data can be restored by following the specified procedure when the trouble
(CD3XX) occurred.
Refer to "Troubleshooting" for details on restoration procedure.
See P.455
Setting/
1. Click [NVRAM Data Backup].
Procedure
2. Click [Start] to start making a backup.
3. Check the message [Backup is completed.], and turn power switch OFF. Wait for ten
seconds or more and turn power switch back ON.
16.17.9

Operation Ban release time

Functions
• To set the time that elapses before the machine releases an access lock that is acti-
vated after the CE password authentication.
Use
• To set the period of time that elapses before the machine releases the access lock,
which aims to prevent the unintentional release of the access lock.
• If the machine is set into an access lock state as a result of CE Authentication, turn
power ON with the Menu/Select key held down; then, on the Trouble Reset screen,
click
timer (set by the Operation Ban release time function).
The access lock state is thereafter released when the period of time set in this func-
tion elapses.
NOTE
• If the access lock state is released through the above procedure, do not turn
power OFF until the time elapses as set through [Service Mode] → [Security
Settings] → [Operation Ban release time]. If the power is turned OFF before the
timer set for Operation Ban release time expires, the lock release operation
becomes invalid.
Setting/
• The default setting is 1 (minutes).
Procedure
NOTE
• When EnhancedSecurity is set to ON in [Admin. Settings] → [Security Set-
tings] → [EnhancedSecurity], the period of time that can be set in this setting
is 5 minutes or more.
380
"Stop"
1 to 60 (minutes)
Field Service Ver. 1.0 Oct. 2007
No Stop
. This starts the access lock release

Advertisement