Level History1; Temp. & Humidity - Konica Minolta bizhub C353P Service Manual

Hide thumbs Also See for bizhub C353P:
Table of Contents

Advertisement

16. Jig Software
16.13.4
Table Number
Functions
• When IDC is detected, for plain paper, Thick 1, Thick, and Black, the machine inde-
pendently displays each Vg/Vdc output value that is calculated based on the density
(toner amount stuck on the belt) of the test pattern created on the transfer belt.
• Reference values: C, M, Y K Vdc: around 400 V, Vg: around 500 V
Use
• Used for troubleshooting of image problems.
Setting/
• If the value is high, correct so that the image density becomes low.
Procedure
• If the value is low, correct so that the image density becomes high.
16.13.5

Level History1

Functions
• To display TCR (T/C ratio), IDC/registration sensor output values, and fusing temper-
ature.
Use
• Used for troubleshooting of image problems.
Setting/
• TCR-C/-M/-Y/-K
Procedure
• IDC1/IDC2
• Temp-Heat
• Temp-Press
"Reading taken last" means
• Density of toner of the latest image.
• When a test print is produced by clicking the Start key while level history 1 is being
displayed.
16.13.6
Level History 2
Functions
• IDC Sensor (Transfer belt bare surface level) as adjusted through the image stabiliza-
tion sequence and ATVC value.
Use
• Used for troubleshooting of image problems.
Setting/
• IDC Sensor: Shows the intensity adjustment value (0 to 255) of the IDC sensor.
Procedure
• ATVC (C, M, Y, K): Shows the first image transfer ATVC adjustment value
• ATVC (2nd)
16.13.7
Temp. & Humidity
Functions
• To display the temperature and humidity of a specific location (AIDC sensor portion)
inside the machine and fusing temperature.
Use
• Used as reference information when a malfunction occurs.
Setting/
• Temp-Inside
Procedure
• Temp-Heater
• Temp-press.
• Humidity
• Absolute Humidity
364
: Shows the T/C output reading taken last.
: Shows the latest IDC data.
: Displays the latest temperature of the heating roller.
: Displays the latest temperature of the pressure roller.
(5 to 40 μA).
: Shows the second image transfer ATVC adjustment value
(300 to 4800 V).
: 0 to 100 °C in 1 °C increments
: 0 to 260 °C in 1 °C increments
: 0 to 260 °C in 1 °C increments
: 0 to 100 % in 1 % increments
: 0 to 100 in 1 increments