Konica Minolta bizhub C353P Service Manual page 722

Hide thumbs Also See for bizhub C353P:
Table of Contents

Advertisement

Field Service Ver. 1.0 Oct. 2007
Y
Z
[1]
Y
Z
A01GF2C013DA
A01GF2C578DA
6. Measure the width of Y and Z (clear-
ance of the exterior parts) on front
and back side.
Specifications:
Y = Z - 1 mm
(Y must be smaller than Z)
Z = 7 ± 2 mm (front side)
Z = 9 ± 2 mm (back side)
NOTE
• To measure the front side, open the
front door and measure it using fin-
isher side as supporting point refer-
ring showed on the illustration left.
7. When the value does not fall within
the specified range, remove the tray
unit and pull up the casters to adjust
them.
NOTE
• For adjusting the casters, hold the
bottom part of the stand table and
turn the adjusting bolt [1].
4. Other
37

Advertisement

Table of Contents
loading

Table of Contents