20. Malfunction code
Code
Item
C11B5 Side staple 1 drive failure
C11B6 Side staple 2 drive failure
C11C0 Punch motor malfunction
C11D0 Crease motor drive failure
C11E0 Unsupported option trouble
C1301 Finishing option cooling
fan motor failure
C2151 Secondary transfer roller
pressure welding alien-
ation
C2152 Transfer belt pressure
welding alienation
C2164 PC charge malfunction
C2253 Color PC motor's failure to
turn
C2254 Color PC motor's turning
at abnormal timing
410
Detection timing
See P.44 of the SD-505 service manual.
See P.81 of the FS-519/PK-515/OT-602 ser-
vice manual.
See P.44 of the SD-505 service manual.
See P.81 of the FS-519/PK-515/OT-602 ser-
vice manual.
• During a retraction operation of the 2nd
image transfer roller, the 2nd image transfer
welding alienation sensor cannot detect the
2nd image transfer roller at its retracted
position within a predetermined period of
time after the 2nd image transfer retraction
motor starts rotating.
• During a pressure operation of the 2nd
image transfer roller, the 2nd image transfer
welding alienation sensor cannot detect the
2nd image transfer roller at its pressed posi-
tion within a predetermined period of time
after the 2nd image transfer retraction motor
starts rotating.
• During a retraction operation of the transfer
belt, the transfer belt retraction sensor can-
not detect the transfer belt at its retracted
position within a predetermined period of
time after the transfer belt retraction clutch is
turned ON.
• During a pressure operation of the transfer
belt, the transfer belt retraction sensor can-
not detect the transfer belt at its pressed
position within a predetermined period of
time after the transfer belt clutch is turned
ON.
• When electrostatic charge output is ON,
electrostatic charge leak detection system
continues to detect leaks for a predeter-
mined period of time.
• The motor lock signal remains HIGH for a
predetermined continuous period of time
while the motor is turning.
• The motor lock signal remains LOW for a
predetermined continuous period of time
while the motor remains stationary.