This table lists the maximum capacity supported for each component type based on the type of
power supply installed on the shelf, total number of cards slots available, software restrictions
and the power consumption of each component. The combined total number of ports for each
system is limited to 1024 ports. Power consumption based on utilizing the IX-PWSE in the IX-
CME ECS cabinet and IX-PWSL in the ADIX APS and expansion cabinets.
Shelf 6
Shelf 5
Shelf 4
Shelf 3
Shelf 2
IX-CME
Shelf 1
Universal Card Slots
6
Number of TDM Ports
2 25
144
Trunk Ports
3 26
144
T1 Ports without T1RCV
144
T1 Ports with T1RCV
0
Station Ports (TDM + IP)
1024
4
27
IP Stations
1024
4 28
ICON DECT1 Base
40
Stations
ICON DECT1 Handsets
30/base
station,
200 max.
Omegatrek Portable Station
1024
(IX-PS6)
IX-BS5 Base Stations
24
TDM Digital Station Ports
72
5
29
Attendant Positions
32
Attendant Consoles
24-w/o BLF
BLF Units
8
DSS Units (IX-DSS-3)
9 30
32
IP DSS Units (59DS)
9 31
64
On-Premise SLTs (Regular)
72
On-Premise SLTs (MSG)
72
Off-Premise SLTs
16
Door Phones
96
Loop Start Trunks
48
Caller ID Trunks
48
Ground Start Trunks
48
E & M Tie Trunks
20
DID Trunks
20
SIP Phones (G.711)
160
25
The combined number of TDM Station, Trunk, and Miscellaneous ports may not exceed the
number of ports listed in this category.
26
This number indicates the maximum trunk port capacity utilizing no T1RCV cards.
27
The ECS supports a maximum of 1024 IP or IP + TDM ports, this number assumes a
minimum of 8 trunk ports supported. (1016 station ports + 8 trunk ports = 1024 total
ports)Maximum of 64 remote IP stations via Internet mode connection.
28
Ibid.
29
The maximum number of TDM station ports per shelf may not exceed 72. This number does
not apply to PS6 Portable Stations.
30
The maximum number of DSS units and attendant consoles in the ECS system cannot exceed
128. The ECS system supports a maximum of 64 Iwatsu ICON Series 59DS units as part of the
128 total.
31
Ibid.
IX-EXPML1
IX-EXPML1
IX-EXPML1
IX-CML
IX-CML
IX-CML
IX-CME
IX-CME
IX-CME
11
17
23
232
328
424
200
256
312
168
168
168
24
72
120
1024
1024
1024
1024
1024
1024
40
40
40
30/base
30/base
30/base
station,
station,
station,
200 max.
200 max.
200 max.
1024
1024
1024
40
64
88
144
216
288
32
32
32
32-8
32
32
w/BLF
24 w/o
BLF
16
24
32
64
96
128
64
64
64
140
212
284
136
208
280
20
24
28
167
240
312
84
132
180
80
128
176
76
124
172
36
60
84
36
60
84
160
160
160
GENERAL DESCRIPTION - 18
IX-EXPML1
IX-EXPML2
IX-EXPML2
IX-EXPML1
IX-EXPML1
IX-EXPML1
IX-EXPML1
IX-CML
IX-CML
IX-CME
IX-CME
29
35
520
616
368
424
168
168
168
216
1024
1024
1024
1024
40
40
30/base
30/base
station, 200
station, 200
max.
max.
1024
1024
112
136
360
432
32
32
32
32
32
32
128
128
64
64
356
428
352
424
32
36
384
456
228
264
224
268
220
260
108
132
108
132
160
160

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enterprise-cs

Table of Contents