With Iwatsu Enterprise-Cs Expansion Hardware - Iwatsu ENTERPROSE-CS Owner's Manual

Table of Contents

Advertisement

With Iwatsu Enterprise-CS Expansion Hardware

This table lists the maximum capacity supported for each component type based on
the type of power supply installed on the shelf, total number of cards slots available,
software restrictions and the power consumption of each component. The combined
total number of ports for each system is limited to 1024 ports. Power consumption
based on utilizing the IX-PWSE in the IX-CME ECS cabinet and IX-EXPWS in the
ECS expansion cabinets.
IX-PWSE
Power Supply
Shelf 6
Shelf 5
Shelf 4
Shelf 3
Shelf 2
IX-CME
Shelf 1
Universal Card Slots
6
Number of TDM Ports
144
15
Trunk Ports
144
T1 Ports w/o T1RCV
144
Station Ports
16
1024
IP Stations
1024
17
ICON DECT1 Base Stations
40
ICON DECT1 Handsets
30/base
station, 200
max.
Omegatrek Portable Station
1024
(IX-PS6)
IX-BS5 Base Stations
24
TDM Digital Station Ports
18
72
Attendant Positions
32
19
Attendant Consoles
24 w/o BLF
DSS Units (IX-DSS-3)
32
20
IP DSS Units (59DS)
64
21
On-Premise SLTs (Regular)
72
On-Premise SLTs (MSG)
72
Off-Premise SLTs
16
Door Phones
96
Busy Bypass Units
36
22
Loop Start Trunks
48
Caller ID Trunks
48
Ground Start Trunks
48
E & M Tie Trunks
20
DID Trunks
20
SIP Phones (G.711)
160
SIP Trunks
248
IX-MSGU Message Cards
5
15
The combined number of TDM Station, Trunk, and Miscellaneous ports may not exceed the
numbers listed in this category
16
The ECS supports a maximum of 1024 IP or IP+TDM ports, this number assumes a minimum
of 8 trunk ports supported
(1016 station ports + 8 trunk ports = 1024 total ports). Maximum
of 64 remote IP stations via Internet mode connection.
17
Ibid.
18
The maximum number of TDM station ports per shelf may not exceed 72. This number does
not apply to PS6 Portable Stations.
19
The maximum number of DSS units and attendant consoles in the ECS system cannot exceed
128. The ECS system supports a maximum of 64 Iwatsu ICON 59DS Units.
20
Ibid.
21
Ibid.
22
When Busy Bypass Units are used, the total number of Digital Stations should not exceed
these numbers.
IX-EXPWS
IX-EXPWS
IX-EXPWS
IX-EXPME2
IX-EXPME1
IX-EXPME1
IX-EXPME1
IX-EXPME1
IX-EXPME1
IX-CME
IX-CME
IX-CME
12
18
240
336
240
336
144
144
1024
1024
1024
1024
40
40
30/base
30/base
30/base
station, 200
station, 200
station, 200
max.
max.
1024
1024
48
72
144
216
32
32
32
32
(8 w/ BLF 24
w/o BLF)
64
96
64
64
144
216
144
216
32
48
192
288
72
108
96
144
96
144
96
144
40
60
40
60
160
160
248
248
8
8
GENERAL DESCRIPTION - 16
IX-EXPWS
IX-EXPWS
IX-EXPME1
IX-EXPME1
IX-EXPME1
IX-EXPME2
IX-EXPME2
IX-EXPME1
IX-EXPME1
IX-EXPME1
IX-EXPME1
IX-CME
IX-CME
24
30
36
432
528
624
432
528
624
144
144
144
1024
1024
1024
1024
1024
1024
40
40
40
30/base
30/base
station, 200
station, 200
max.
max.
max.
1024
1024
1024
96
120
144
288
360
432
32
32
32
32
32
32
128
128
128
64
64
64
288
360
432
288
360
432
64
80
96
384
480
576
144
180
216
192
240
288
192
240
288
192
240
288
80
100
120
80
100
120
160
160
160
248
248
248
8
8
8