Extra Functions (In The Application Menu); Second Tare Memory (Preset Tare) - Sartorius Factory Series Operating Instructions Manual

Factory series electronic precision scales
Table of Contents

Advertisement

Extra Functions
(in the Application Menu)
Second Tare Memory
(Preset Tare)
Purpose
With this function, you can store the
weight currently on the scale as a tare
weight, or use the numeric keys to
enter a number for a preset tare weight.
You can use this function in
combination with a program from
Application 1 (such as counting,
weighing in percent), one from Appli-
cation 2 (checkweighing,
time-controlled functions) and one
from Application 3 (totalizing,
formulation, statistics) as well as
with the extra functions.
Features
– Store a weight on the scale
in the second tare memory (without
numeric input)
– Store a numeric value in the
second tare memory (input using
the numeric keys)
– Identify a net value as s when
there is a value stored in the
second tare memory
– You can assign this function to the
fourth or fifth soft key (from the
right); i.e., F4 or F5.
The soft key designation for this
function is:
PT1/T1
– Optional configuration in the Setup
menu for storing the current weight
readout as the container tare
weight. Any load subsequently
placed on the scale that is more
than 70% of the tare weight is
automatically recognized as a
container and the scale is tared
automatically.
– Automatic printout when
a value is stored or input (see
"Configuring the Scale")
– Press c to delete the (preset) tare
value
134
Factory Settings
Container tare weight:
No
Automatic printout:
Off
Soft Key Functions
Store weight as tare value
PT1/T1
Store input value
PT1
Preparation
Turn on the scale: press e
> The Sartorius logo is displayed; a self-test is performed
Select Extra function (F4) or Extra function (F5) in the Setup menu: press M
FC Models:
§ Select the Application menu:
§ Select
Extra func. (F4)
FCA Models:
Select
Application parameters
then the O soft key once
Select
Extra function (F4)
press the q soft key 3 x (or 4 x), then press the O soft key once
Select
2nd tare memory
Confirm
2nd tare memory
2nd
Container tare
tare memory
weight
Automatic
printout
ο = factory setting
see also the "Application Parameters (Overview)" in the chapter entitled
"Configuring the Scale"
Save settings and exit the Setup menu: press the oo soft key
Second Tare Memory in Legal Metrology
– Press the
soft key to enter information about the tare value using
(i)PT1
the number keys.
– The PT1 tare value is printed out with the net value.
Printout of the Data in the
2nd Tare Memory
The printout shows either
– Net value N1,
– Tare weight T1, or
– Manually entered tare value PT1
N1
63.48 g
T1
138.73 g
PT1
150.00 g
N1: Net weight (value) when
a weight is stored in the tare
memory
T1: Tare weight
PT1: Preset tare value entered using
the numeric keys
soft key
App
or
Extra func. (F5)
: press the q soft key 2 x,
or
Extra function (F5)
ο No
Yes
Net value
Tare/preset
ο Off
:

Hide quick links: