Sartorius Factory Series Operating Instructions Manual page 122

Factory series electronic precision scales
Table of Contents

Advertisement

Preparation
Turn on the scale: press e
> TheSartorius logo is displayed; a self-test is performed
Select the "Totalizing" application program in the Setup menu: press M
FC Models:
§ Select the Application menu:
§ Select
Application 3
FCA Models:
Select the
Application parameters
then the O soft key
Select
Application 3 (data records)
press the q soft key 2 x, then the O soft key once
Select
: press the Q or q soft key
Totalizing
Confirm
Totalizing
Totalizing
Automatic
storage
Minimum load for
automatic storage
Source of data
for automatic storage
Evaluated values
Evaluation mode,
MR function
M+/M– function,
then tare
Printout of individual
components
ο = factory setting
see also the "Application Parameters (Overview)" in the chapter entitled
"Configuring the Scale"
Save settings and exit the Setup menu: press the oo soft key
122
soft key
App
: Press the q soft key and then the O soft key
: press the q soft key 2 x,
:
: press the O soft key
ο Off
On, first value at stability
On, last value at stability
On, value bet. 70 - 130% at stabil.
None
ο 10 digits
20 digits
50 digits
100 digits
200 digits
500 digits
1000 digits
ο Application 1
Application 2
ο Net
Calculated
Net + calculated
ο Intermediate evaluation, print
Final evaluation, print
Intermediate evaluation, display + print
Final evaluation, display + print
ο Off
On
No
ο Yes
Additional Functions
In addition to the functions for:
– alphanumeric input,
– taring (not during alphanumeric
input),
– printing,
you can also access the following
functions from this application:
Calibration/Adjustment
Press the
soft key
isoTST
> See "Calibration/Adjustment"
for further instructions
Toggling to Another Application
Press D
> See the section on the
corresponding application
program for further instructions
Setup (Setting Parameters)
Press M
> See "Configuring the Scale" for
further instructions
Turning Off the Scale
Press e
> The scale shuts off
> The display goes blank, then
OFF or Standby is displayed with
backlighting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Factory fcFactory fca

Table of Contents