Event Notification Response

When you select Event Notification, WebPAM PROe sends popup and/or email
messages regarding its status. The messages you see depend on your
notification selection and what is currently happening in the VTrak. See "Setting-
up User Event Subscriptions" on page 73.
The table below cites:
Reported Events – Events that require you to take action
Corrective Actions – The action you should take in response to the event
A list of event categories is shown below.
Battery (page 274)
Blowers (page 275)
Cache (page 276)
Controller (page 276)
Disk Array (page 276)
Drive Interface Controller
(page 277)
Enclosure (page 277)
Event Log (page 277)
Fibre Channel (page 278)
Host Interface Controller
(page 278)
Logical Drive (page 279)
Media Patrol (page 280)
Online Capacity Expansion
(page 280)
PDM (page 281)
Reported Event
Battery
Battery temperature is
above the threshold
Battery temperature is
normal
Battery capacity is below
the threshold
Physical Disk (page 281)
PSU (Power Supply Units)
(page 283)
PSU Fans (page 283)
RAID Level Migration (page 283)
Rebuild (page 284)
Redundancy Check (page 285)
Resource (page 285)
Spare Check (page 285)
Spare Drives (page 286)
SMART (page 286)
Stripe Level Migration (page 286)
Synchronization (page 287)
System (VTrak) (page 287)
Transition (page 287)
Watermark (page 288)
The battery is too hot. Verify proper airflow around
the through the VTrak. If airflow is OK, replace the
battery. See page 224.
Normal.
Battery is drained. Run battery reconditioning. See
page 114 or page 160.
274
Corrective Action