Running Redundancy Check; Locating A Logical Drive - Promise Technology VTRAK E610f Product Manual

E-class
Hide thumbs Also See for VTRAK E610f:
Table of Contents

Advertisement

VTrak E-Class Product Manual
Quick Initialization – Yes means only the first and last sections of the
logical drives are initialized. No means the entire logical drive is
initialized.
Quick Initialization Size – Enter a value for the first and last sections of
the logical drive to be initialized or use the default 64 MB.
To change a parameter, highlight it and press the backspace key to erase
the current value, then type the new value.
5.
Highlight Start and press Enter.
If necessary, you can pause and resume or stop and restart the Initialization.
You cannot access the logical drive until Initialization has finished.

Running Redundancy Check

Redundancy Check is a maintenance procedure for logical drives in fault-tolerant
disk arrays that ensures all the data matches exactly. To run Redundancy Check:
1.
From the Main Menu, highlight Logical Drive Management and press Enter.
2.
Highlight the logical drive you want and press Enter.
3.
Highlight Background Activity and press Enter.
4.
Highlight Start Redundancy Check and press Enter.
The redundancy check parameters appear.
Auto Fix – Corrects inconsistencies automatically
Pause On Error – Pauses the Redundancy Check when an error is
found
To change a parameter, highlight it and press the backspace toggle between
Yes and No.
5.
Highlight Start and press Enter.
If necessary, you can pause and resume or stop and restart the Redundancy
Check. You can use the logical drive while Redundancy Check is running.

Locating a Logical Drive

This feature helps you identify the physical drives assigned to the logical drive
you are working with in the CLU. To locate a logical drive:
1.
From the Main Menu, highlight Logical Drive Management and press Enter.
2.
Highlight the disk array you want and press Enter.
3.
Highlight Locate Logical Drive and press Enter.
The drive status LEDs for the physical drives in this logical drive will blink for
one minute.
178

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vtrak e310fVtrak e610sVtrak e310s

Table of Contents