Promise Technology VTRAK E610f Product Manual page 300

E-class
Hide thumbs Also See for VTRAK E610f:
Table of Contents

Advertisement

VTrak E-Class Product Manual
Reported Event
Spare check completed
successfully on the given
spare drive
Spare Drives
Physical disk assigned as
global spare
Physical disk is no longer
assigned as global spare
Global Spare has been
deleted
Physical disk assigned as
dedicated spare
Physical disk is no longer
assigned as dedicated
spare
Dedicated Spare has
been deleted
SMART
SMART error is received
Stripe Level Migration
Stripe Level migration is
started
Stripe Level migration is
completed
Stripe Level migration is
paused
Stripe Level migration is
resumed
Stripe Level migration is
stopped
Stripe Level migration has
encountered a physical
disk error
Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
A disk drive reported a SMART error. If this message
appears repeatedly, replace the disk drive.
Result of settings or user action. Normal.
Normal.
Migration paused because of user intervention,
schedule or a higher priority background activity.
Migration has resumed again after a pause.
Migration stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.
Bad block found on a disk drive. Migration will finish.
Check the disk drive check table after migration and
replace disk drive as needed. See page 138.
286
Corrective Action

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vtrak e310fVtrak e610sVtrak e310s

Table of Contents