Promise Technology VTRAK E610f Product Manual page 292

E-class
Hide thumbs Also See for VTRAK E610f:
Table of Contents

Advertisement

VTrak E-Class Product Manual
Reported Event
Fibre Channel
Fibre Channel controller
has detected bus reset
Fibre Channel controller
has received a LUN reset
command.
Fibre Channel controller
has encountered a fatal
error
Fibre Channel link is up
Fibre Channel link is
down
Fibre Channel controller
settings have changed
Host Interface Controller
Host-interface controller
has detected bus reset
Host-interface controller
has encountered an
unrecoverable error
Host-interface controller
has received an abort-
task/ abort task set/clear
task set command.
Host-interface controller
has received an clear
ACA command.
Host-interface controller
has received a LUN reset
command.
Host-interface controller
has received a bus reboot
Host-interface controller
has encountered an
unknown error
The initiator sent a reset command. If this message
appears repeatedly, contact Technical Support. See
page 305.
Result of user action. Normal.
Restart the VTrak. See page 215. If this message
appears repeatedly, contact Technical Support. See
page 305.
FC link connected and ready. Normal.
FC link disconnected or otherwise not working.
Result of user action. Normal.
The initiator sent a reset command. If this message
appears repeatedly, contact Technical Support. See
page 305.
Restart the VTrak. See page 215.
Result of user action. Normal.
Result of clearing an auto contingent alliance
condition. If this message appears repeatedly,
contact Technical Support. See page 305.
Result of user action. Normal.
The VTrak rebooted itself. If this message appears
repeatedly, contact Technical Support. See page 305.
An unidentified error occurred. If this message
appears repeatedly, contact Technical Support. See
page 305.
278