Managing Spare Drives; Viewing A List Of Spare Drives; Locating A Spare Drive - Promise Technology VTRAK E610f Product Manual

E-class
Hide thumbs Also See for VTRAK E610f:
Table of Contents

Advertisement

Managing Spare Drives

When a physical drive in a disk array fails and a spare drive of adequate capacity
is available, the disk array will begin to rebuild automatically using the spare
drive. See "Critical & Offline Disk Arrays" on page 289.
Spare drive management includes the following functions:
Viewing a List of Spare Drives (page 141)
Locating a Spare Drive (page 141)
Creating a Spare Drive (page 142)
Deleting Spare Drive (page 143)
Making Spare Drive Settings (page 143)
Running Spare Check (page 144)

Viewing a List of Spare Drives

To view a list of spare drives:
1.
Click the Subsystem
2.
Click the Spare Drives
The information includes:
ID – The unique ID number assigned to the spare drive.
Operational Status – OK is normal. Can also show Rebuilding, Transition
Running, PDM Running, or Offline.
Physical Drive ID – The ID number of the physical drive in the subsystem
enclosure.
Capacity – The data storage capacity of this spare drive.
Revertible – Yes or No. A revertible spare drive automatically returns to its
spare drive assignment after the failed physical drive in the disk array is
replaced.
Type – Global, can be used by any disk array. Dedicated, can only be used
by the assigned disk array.
Dedicated to Array – For dedicated spares, the disk array to which it is
assigned. Global spares show N/A.

Locating a Spare Drive

To locate a physical drive assigned as a spare drive in the VTrak subsystem
enclosure:
1.
Click the Subsystem
2.
Click the Spare Drives
Chapter 4: Management with WebPAM PROe
icon in Tree View.
icon.
icon in Tree View.
icon.
141