Promise Technology VTRAK E610f Product Manual page 289

E-class
Hide thumbs Also See for VTRAK E610f:
Table of Contents

Advertisement

Reported Event
Battery capacity is normal Normal.
Battery is discharging
Battery is charging
Battery reconditioning is
complete
Battery is malfunctioning
Battery reconditioned
successfully
Battery reconditioning has
failed
Battery is reaching end of
life
Battery is removed
Battery charging failed
Battery reconditioning
started
Battery recondition
terminated
Blowers
Blowers have started
Blowers have stopped
Blower speed is
increased
Blower speed is
decreased
Blowers are NOT
functioning
Blowers have been
inserted
Battery is undergoing reconditioning.
Battery is being recharged.
Battery reconditioning is finished.
Run battery reconditioning. See page 114 or
page 160. If this message reappears, replace the
battery.
Battery reconditioning is finished.
Replace the battery. See page 224.
Replace the battery. See page 224.
The battery was disconnected or removed. Reinstall
the battery. See page 224.
Replace the battery. See page 224.
Battery reconditioning has begun.
The battery was disconnected or removed during
reconditioning. Reinstall the battery. See page 224.
Normal.
Verify that the cooling unit is properly installed. If the
blower still does not turn, replace the blowers. See
page 219.
Check the VTrak for overheating. See page 295.
Temporary overheat condition was corrected.
Replace the blowers. See page 219.
Normal.
275
Chapter 8: Troubleshooting
Corrective Action

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vtrak e310fVtrak e610sVtrak e310s

Table of Contents