Enclosure Warning Temperature Threshold
Enclosure Critical Temperature Threshold
Controller Warning Temperature Threshold
Controller Critical Temperature Threshold
6.
Click the Submit button.
The changes take effect immediately.

Viewing FRU VPD Information

FRU VPD refers to Vital Product Data (VPD) information about Field Replaceable
Units (FRU) in the enclosure. The number and type of FRU depends on the
subsystem model.
To view FRU VPD information:
1.
Click the Subsystem
2.
Click the Enclosures
3.
Click the Enclosure
4.
Click the FRU VPD tab in Management View.
Use this information when communicating with Technical Support and when
ordering replacement units. For contact information, see "Contacting Technical
Support" on page 305.

Checking the Batteries

The Enclosure–Battery tab displays information about the cache backup battery
(or batteries) in the VTrak subsystem enclosure. To check the batteries:
1.
Click the Subsystem
2.
Click the Enclosures
3.
Click the Enclosure
4.
Click the Battery tab in Management View.
Battery Notes
Each battery works with a controller. If the battery is present in the subsystem but
the corresponding controller is not present, the battery will not appear in the
interface.
If a battery does not reflect normal conditions and it is not currently under
reconditioning, run the Recondition function before you replace the battery. See
"Reconditioning a Battery" on page 114.
Reconditioning fully discharges, then fully recharges the battery. During
reconditioning, if the Adaptive Writeback Cache function is enabled, the controller