Restarting the Subsystem

There are two methods for restarting the subsystem. Choose one of the following
procedures:
Restarting the Subsystem (page 211)
Restarting VTrak – Serial Connection (page 211)
Restarting VTrak – Telnet Connection
This function enables you to restart the VTrak subsystem on a Telnet connection.
You can only do part of this procedure in the CLU. Additional action is required,
as described below. To restart the VTrak:
1.
From the Main Menu, highlight Additional Info and Management and press
Enter.
2.
Highlight Shutdown or Restart and press Enter.
3.
Highlight Option and press the spacebar to display Restart.
4.
Highlight Submit and press Enter.
A warning message appears.
5.
Press Y to continue.
The screen will go blank.
6.
Wait for no less than two minutes.
7.
Re-establish your Telnet connection to the VTrak CLU.
If you cannot re-establish a connection, wait 30 seconds, then try again.
Restarting VTrak – Serial Connection
This function enables you to restart the VTrak subsystem on a serial connection.
You can only do part of this procedure in the CLU. Additional action is required,
as described below. To restart the VTrak:
1.
From the Main Menu, highlight Additional Info and Management and press
Enter.
2.
Highlight Shutdown or Restart and press Enter.
3.
Highlight Option and press the spacebar to display Restart.
4.
Highlight Submit and press Enter.
A warning message appears.
5.
Press Y to continue.
The screen will display shutdown and startup functions.
6.
When the
Login:
prompt appears, log into the CLU again.