VTrak E-Class Product Manual
Support for the industry standard Disk Data Format (DDF from SNIA)
ensures interoperability and drive roaming even among different RAID
vendors
Compatible with leading SAS hard drives, host bus adapters and RAID
controllers

Subsystem and Controller Features

Controllers: Dual-controller configuration or single-controller configuration,
upgradeable to dual. Dual-controller subsystems feature Active/Active, Failover/
Failback.
Drive Support: Up to 16 (E610f/s) or 12 (E310f/s) 3.5" x 1" hard disk drives: SAS
3Gb/s, SATA II 3Gb/s and 1.5Gb/s. SATA drives require an AAMUX Adapter in
dual I/O module configuration (dual-controller) subsystems.
Supports any mix of SAS and SATA II 3Gb/s or 1.5Gb/s drives simultaneously in
the same system. Staggered physical drive spin-up.
External I/O Ports (per controller): Dual 4-Gb Fibre Channel host port; One
external 3 Gb/s SAS x4 ports for JBOD expansion (up to four VTrak JBOD
Systems).
Data Cache: Shared 512 MB predictive data cache (expandable to 2 GB);
Automatic write cache destaging; 72-hour battery backup (for 512 MB cache).
Command Queue Depth: 512 commands per VTrak system (up to 1024
commands with 512 MB memory).

Operational Features

RAID Levels: RAID 0, 1, 1E, 5, 6, 10, 50, and 60 – Any combination of these
RAID levels can exist at the same time.
Configurable RAID stripe size: 64 KB, 128 KB, 256 KB, 512 KB, and 1 MB stripe
size per logical drive.
Background task priority tuning: Adjustment of minimum I/O reserved for server
use during all background tasks.
Hot spares: Multiple global or dedicated hot-spare drives with revert option.
Maximum LUNs per subsystem: 256 in any combination of RAID levels.
Maximum LUNs per array: 32 logical drives (LUNs). Supports LUN carving by
allowing an array to be divided into multiple logical drives. Supports out-of-order
logical drive deletion and re-creation.
Max LUNs per Target ID: Up to 256, depending on host side driver and operating
system.