Activating Partitions; On The System; Using The Wireless Remote Control - Abus Secvest 2Way Operating Instructions Manual

Hide thumbs Also See for Secvest 2Way:
Table of Contents

Advertisement

11. Activating partitions

If the alarm system is set up so that two or more partitions can be monitored independently of each other, these partitions can now be individually activated or
deactivated. A user can now activate/deactivate one or more partitions, depending on the user authorisation. If the entire alarm system is activated, each partition is
also activated. If the user is authorised to activate one partition only, then this partition can be activated by entering the user code. If the user is authorised to
activate two or more partitions, then they must now select the partition to be activated. Partitions can also be activated/deactivated using the remote control or the
arming station. The remote control has the same authorisation as its assigned user.

11.1. On the system

Enter your user code or hold your chip key over
the system reader. If you are authorised to
activate more than one partition, the following
graphic display is shown:
Select "Partitions".
Select the partition to be activated.
When activation is confirmed, the system starts the delay time for the corresponding partition. At the same time,
the system emits an acoustic message. This is as follows:
"Partition activated"
If the user activates all partitions for which they have authorisation, the message is as follows:
"Alarm system activated"
Change the settings for this partition.
The displayed codes next to the partition have
the following meanings:
Display
Meaning
U
This partition remains deactivated.
U>P
This partition is activated internally.
U>S
This partition is activated.
S>U
This partition is deactivated.
P>U
This partition is deactivated
internally.
S
This partition remains activated.
P
This partition remains activated
internally.
To activate one or more partitions, select U>S
next to the corresponding partition.
Confirm your entry by pressing Done.
The system then carries out the entered actions
(activation/deactivation).
13
11.2. Using the wireless remote
control
Using the FU5155 / FU5150 remote control unit,
partitions can be activated in two ways:
a) The remote control activates all partitions
within the user's authorisation.
b) The keys of the remote control unit are
programmed in the user menu to activate
partitions individually.
Example of key settings:
Complete activation (partitions 1 and 3)
Activate
Activate
partition
partition 3
Complete deactivation
See also "System Config".

Advertisement

Table of Contents
loading

Table of Contents