16.4

Programming Partitions

If you are using a partitioned system then you can use the
following commands for programming the partitions.
1. Use the commands 01 to 16 and X17 to X32 to assign
a partition to each zone.
- each zone belongs to partition A (factory setting).
- Press key A to assign zones to partition A. Use keys
B, C and D to assign zones to the respective partition.
2. Use command 32 to assign control units to partitions.
In the default setting, all control units belong to all
partitions.
Command changes for partitioned systems
Some commands provide new functions for partitioned systems and some commands can no longer be used. The following
table gathers together the differences in the programming:
Command
01-40 zone programming
28 mask out the status display
32 control units and partitions
39 location/partition A exit mode
47 partition A alarm report
60 zone behaviour for internal B (last exit)
61 zone behaviour for internal B (entry zone)
62 exit mode for internal B
63 alarm behaviour for internal B
70 zone behaviour for internal C (last exit)
71 zone behaviour for internal C (entry zone)
72 exit mode for internal C
73 alarm behaviour for internal C
76 exit mode for internal D
77 Alarm behaviour for internal D
81, 82, 83, 84 exits
3. Programming from exit mode, alarm reaction and exit
time:
Partition
A
Exit
Com. 39
mode
Alarm
Com. 47
reaction
Exit time
Com. 44
4. You can assign siren outputs to each partition using
commands 81 to 84.
- Option 18 assigns the output to partition A.
- Option 19 assigns the output to partition B.
- Option 20 assigns the output to partition C.
- Option 21 assigns the output to partition D.
5. Make sure that the main user is instructed on how to
assign individual user codes to partitions.
Partition System
A – D = partitions
partition active
control unit assigned to part.
B
option 3 and 4 possible
function possible
no function
no function
options changed
options changed
no function
no function
options changed
options changed
options changed
options changed
18-21=Siren Partition
85
B
C
D
Com. 62
Com. 72
Com. 76
Com. 63
Com. 73
Com. 77
Com. 65
Com. 75
Com. 79
Single System
A – D = sections of locations
location active
no function
option 3 becomes Lockset
option 4 is not possible
no function
function possible
function possible
function possible
function possible
UK