Download Print this page

Tips For Self-Help In The Case Of Faults - Meiko K-Tronic Service Manual

Basket transport dishwashing machine

Advertisement

Operating instructions dishwashing machine model K-Tronic
Datei:2K_9626212_Betriebsanleitung-MIKE_EN_2005-12-01.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: 0781/203-0, Fax: 0781/203-1174
10

Tips for self-help in the case of faults

Fault:
Machine does not fill.
Fault:
Rinse water does not
spray.
Fault:
Vapours drains
Fault:
Stripes and smears on the
dishes
gültig ab: 2003-01
W e reserve the right to change execution and construction!
Remedy
• No water available
• Dirt trap blocked
• Level electrode / float valve soiled
• Solenoid valve defective
Remedy
• No water available
• Dirt trap blocked
• Solenoid valve defective
• If the appliance has automatic water conservation, the
conservation grid switch / timing switch is defective
• Fresh water rinse system furred
• Built-in reverse osmosis installation broke down
Remedy
• Extraction broke down
• Curtains missing
• Temperatures too high
• Wash arms, drying nozzles, air guide plates bent or
not correctly inserted
Remedy
• Rinse water mineral content too high (see operating
instructions)
• If this is observed only at particular times, check water
softener for regeneration. This must not carried out
during the dishwashing operation.
• Water pre-treatment defective or not carried out
• Different water type depending on the waterworks
• Unsuitable rinse aid products or wrong dosage
quantity
• Incorrectly fitted or missing curtains
• Oversize containers previously washed causing
detergent to be transferred into following tanks
• Too fast conveyor speed
Ident-Nr.: 9619165
Update: 2004-05-07
24/38