Download Print this page

W E Reserve The Right To Change Execution And Construction; Other Possible Malfunctions - Meiko K-Tronic Service Manual

Basket transport dishwashing machine

Advertisement

Service Instructions Dishwashing Machine Model K-Tronic

8.3 Other possible malfunctions

Situation
Nothing works,
everything dark,
buzzer off
Nothing works,
no text on LCD,
background
illumination on,
buzzer on
LCD dark and dots
missing; otherwise
normal function.
Infra-red
communication not
possible.
CPU is reset
during course of
program.
CPU continually
initialised.
All LEDs activated
(flashing).
Membrane key-pad
not working
correctly.
No reaction to any
key on the
membrane key-pad
Datei: 2K_9628652_Serviceanleitung-MIKE_EN_2005-09-01.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174
Result / Reaction Possible causes
LED on the circuit
12V power supply (power pack)
board not ON
not available;
overload due to short circuit in the
low tension area
LED on the circuit
EPROM missing or wrongly
board not ON
connected
LCD defective
Membrane key-pad dirty;
Parameterisation error
Display dark for a
Overload on the switching mode
short time; the
power supply,
controls are then
short circuit in consumer;
initialised.
power failure to the building
Not possible to
IrDa interface overloaded
start the program
Not possible to
Short circuit caused by damp in
operate the
the membrane key-pad or in the
machine
connecting plug/jack
Allocation of the
The membrane key-pad is not
program selected
properly plugged into the CPU
and the reaction
do not coincide
Machine cannot
The membrane key-pad is not
be used
connected to the CPU
valid from: 2005-09-01

W e reserve the right to change execution and construction!

Update: 2006-11-14 / S.5
Possible measures
Check function of power-pack
Check EPROM and correct if
necessary.
Change CPU
Test communication by RS232.
Change EEPROM if necessary
and change CPU.
Identify cause by disconnecting
individual consumers.
Interrupt communication
Disconnect membrane key-pad
connecting plug/jack and test
program start by external button;
change membrane key-pad. Test
the button;
change membrane key-pad
Connect the connector correctly.
Check the plug connector
Page 27/30
Ident No.: 9627429

Hide quick links:

Advertisement

Chapters

loading