Tips For Self-Help In The Case Of Faults - Meiko K-Tronic Operating Instructions Manual

Dishwashing machine
Hide thumbs Also See for K-Tronic:
Table of Contents

Advertisement

Operating instructions dishwashing machine model K-Tronic
Datei:BA-K-tronic_MIKE_9626212_EN_2005-12-01.doc
MEIKO Maschinenbau GmbH & Co. KG, Englerstraße 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
12

Tips for self-help in the case of faults

Fault:
Machine does not fill
Fault:
Rinse water does not
spray
Fault:
Vapours drains
Fault:
Stripes and smears on the
dishes
W e reserv e the right to change execution and construction !
Remedy
 No water available
 Dirt trap blocked
 Level electrode / float valve soiled
 Solenoid valve defective
Remedy
 No water available
 Dirt trap blocked
 Solenoid valve defective
 If the appliance has automatic water conservation, the
conservation grid switch / timing switch is defective
 Fresh water rinse system furred
 Built-in reverse osmosis installation broke down
Remedy
 Extraction broke down
 Curtains missing
 Temperatures too high
 Wash arms, drying nozzles, air guide plates bent or not
correctly inserted
Remedy
 Rinse water mineral content too high (see operating
instructions)
 If this is observed only at particular times, check water
softener for regeneration. This must not carried out
during the dishwashing operation.
 Water pre-treatment defective or not carried out
 Different water type depending on the waterworks
 Unsuitable rinse aid products or wrong dosage quantity
 Incorrectly fitted or missing curtains
 Oversize containers previously washed causing
detergent to be transferred into following tanks
 Too fast conveyor speed
30/44
9626212

Advertisement