Download Print this page

W E Reserve The Right To Change Execution And Construction - Meiko K-Tronic Service Manual

Basket transport dishwashing machine

Advertisement

Service Instructions Dishwashing Machine Model K-Tronic
310
Temperature FR
too high
Temperature FR
311
too low
312
FR sensor shortcut
FR sensor break
313
314
FR sensor shortcut
FR2 sensor break
315
FR: flow too low
316
FR2: flow too low
317
Temperature FR2
318
too high
Temperature FR12
319
too low
Malfunction pump PKSP
320
321
Malfunction pump KSP1
Malfunction pump KSP2
322
Overload compressor
510
Heat pump exhaust air
511
fan
512
Heat pump tank water
circulation pump
513
Heat pump low
pressure
Heat pump
514
overpressure
Datei: 2K_9628652_Serviceanleitung-MIKE_EN_2005-09-01.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174
FR1/2
Actual temperature in FR too high
(maximum exceeded)
Contactor sticking; temperature sensor
defective;
Plug contact temperature sensor with
high resistance
Required temperature permanently too
low
Heating element defective; Water
transfer;
Insufficient heating capacity
Short circuit FR temperature sensor
Short circuit in the wiring; Damp in the
connector.
Cable to FR temperature sensor broken.
Connector incorrectly connected; Crimp
connection inadequate
Short circuit FR2 temperature sensor
Short circuit in the wiring; Damp in the
connector.
Cable to FR2 temperature sensor
broken.
Connector incorrectly connected;
Crimp connection inadequate
Volume flow too low (no water)
Mains separation pump; Filling valve
Volume flow too low (no water )
Mains separation pump; filling valve
Actual temperature in FR2 too high
(maximum exceeded)
Contactor sticking; temperature sensor
defective;
Plug contact temperature sensor with
high resistance
Required temperature permanently too
low
Heating element defective;
Water transfer;
Insufficient heating capacity
Signal "circulation pump error of PKSP "
pending
Motor overload switch triggered
Signal "circulation pump error of KSP1"
pending
Motor overload switch triggered
Signal "circulation pump error of KSP2"
pending
Motor overload switch triggered
Heat pump
Motor overload switch compressor
Motor overload switch exhaust air fan
Motor overload switch
Tank water circulation pump
Low pressure switch has caused
disconnection
Overpressure switch has caused
disconnection
valid from: 2005-09-01
Update: 2006-11-14 / S.5

W e reserve the right to change execution and construction!

Page 25/30
Ident No.: 9627429

Hide quick links:

Advertisement

Chapters

loading