Service Instructions Dishwashing Machine Model K-Tronic
Err.
Display
No.
801
Communication with
CAN-bus address 1
802
Communication with
CAN-bus address 2
Communication with
803
CAN-bus address 3
Communication with
804
CAN-bus address 4
Communication with
805
CAN-bus address 5
806
Communication with
CAN-bus address 6
Communication with
807
CAN-bus address 7
808
809
Undefined bus address
recognized
900
No I/O type defined
901
IO type on bus addr.1
incompatible
IO type on bus addr.2
902
incompatible
IO type on bus addr.3
903
incompatible
IO type on bus addr.4
904
incompatible
IO type on bus addr.5
905
incompatible
IO type on bus addr.6
906
incompatible
IO type on bus addr.7
907
incompatible

8.2 Error indication, restricted wash process possible

Info
Display
No.
10
Water change
completed
11
Basic cleaning
completed
Repair OK
12
Maintenance OK
13
Datei: 2K_9628652_Serviceanleitung-MIKE_EN_2005-09-01.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174
Note / Possible causes
CAN communication
Communication cable not connected;
CAN address switch wrongly set.
No power supply to I/O circuit board;
I/O circuit board defective.
See above
See above
See above
See above
See above
See above
Undefined bus users recognized
(CAN address switch wrongly set).
Wrong parameterization
(P310,311,..,323=0)
Wrong I/O type (P310) with CAN addr. 1
Faults through light sources with infrared
component
-> deactivate the infrared communication
via P129 for testing
Wrong I/O type (P311) with CAN addr. 2
Wrong I/O type (P312) with CAN addr. 3
Wrong I/O type (P313) with CAN addr. 4
Wrong I/O type (P314) with CAN addr. 5
Wrong I/O type (P315) with CAN addr. 6
Wrong I/O type (P316) with CAN addr. 7
Note / Possible causes
System
Only manual entry possible
(Operation diary)
Only manual entry possible
(Operation diary)
Only manual entry possible
(Operation diary)
Automatic entry on reset of maintenance
counter
(see parameter P101)
valid from: 2005-09-01
Update: 2006-11-14 / S.5

W e reserve the right to change execution and construction!

Possible measures
Connect.
Settings as in the circuit
diagram
Ensure power available
Replace I/O circuit board
Switch main switch off and
back on
Check address switch;
correct parameter set
Correct parameter set
Check I/O type;
Correct parameter set
Check I/O type;
Correct parameter set
Check I/O type;
Correct parameter set
Check I/O type;
Correct parameter set
Check I/O type;
Correct parameter set
Check I/O type;
Correct parameter set
Check I/O type;
Correct parameter set
Possible measures