7 PARAMETERISE

The following describes how the user can set and adjust process parameters at a later
date. Different user access levels have been realized:
Operating level ->
All users (see chapture operating level)
Operating the machine
Acknowledging faults
Reading out counter statuses (see information output)
User level (level 1)
->
Access by entering a code (5 figures)
10000
read
10001
edit
Several sub-menus:
- View / amend list of configuration parameters
- Conveyor backwards (only as long as the button is activated)
- Set date + time
Technician level (level 2) ->
Access by entering a code (5 figures)
20000
read
20022
edit
The user parameter list will be extended depending on the user level!
Further sub-menus (including user level):
- View / Control outputs (see "Manual Operation")
- Rinse water manual measuring (1 min.)
Refilling cycles (option)
-
Modification depending on the access level:
view / amend transport (including I/O allocation)
-
view / amend KV resp. CSS Top (including I/O allocation KV)
-
view / amend PW (including I/O allocation PW)
-
-
view / amend WT 1 .. 7 (including I/O allocation WT)
-
view / amend PAR (including I/O allocation PAR)
view / amend FR 1.2 (including I/O allocation WT)
-
view / amend drying (including I/O allocation Drying)
-
-
view / amend heat pump (including I/O allocation heat pump)
-
view / amend global I/O allocation
view / amend wash programs 1 .. 20
-
Generally is valid:
The following 6 buttons are used for dialogue in the parameter levels:
Arrow keys
or
Arrow keys
or
value
key - Accept value or selection (see Return);
- or changeover from view mode to edit mode
key - Leave the menu item (cf. the ESC key); in the edit mode you will be asked if
the amendment you have just entered should be deleted and not saved. (Exception for
the operation diary: Key
The corresponding feedback responses are realized via the LCD module.
(The membrane key-pad LEDs are dark in parameterization mode).
If the
or
key (change value) is pressed for a longer period (e. g. 1 second) an
auto-repeat function is activated; in other words, the list of possible values will be shown
valid from: 2005-09-01

W e reserve the right to change execution and construction!

"Specialist distributors"
Official Meiko works representatives:
- Browse the parameter list, change values (up / down)
- Change to variable following to the left or right of the actual
)
Update: 2006-11-14 / S.5
Page 13/30