10. Machine housing and built-in components
Check machine housing, tank, doors for watertightness
Check machine housing, tank, sheet metal body, doors, sub-structure
cladding, entry and discharge sections as well as flaps for damage and for
correct position. Check that all are complete and correctly inserted.
Check sub-structure cladding, entry and discharge sections for damage
and if they are complete.
Check the splash curtains for damage and correct position and if they are
complete
Check tank covering screens and screen box for damage and correct
position and if they are complete
Check door guide rails
Check door roller springs (exchange all even if only one is defective)
Check electrical door control switch function
Check door control switch for mechanical damage
11. Equipment area
Checks on operating temperature and water consumption
Measure tank water temperatures (
drying temperatures (
) and compare with values in the documentation
x4
see later
x2, x3, x4,
Heating system
Check the complete system for watertightness
Clean dirt trap
Check function of the valves
Clean water system (Chapt.15)
Check the complete system for watertightness
Clean dirt trap
Check function of the valves
Clean level control
Check level control function
Check water supply quality – water hardness (acc. to the installation plan)
Check machine and all components for lime-scale deposits. Descale, if
necessary
Check water supply quality – conductivity
reverse osmosis water
Check water supply quality – temperatures (acc. to the installation plan)
see later
x5
Datei:2K_9626212_Betriebsanleitung-MIKE_EN_2005-12-01.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: 0781/203-0, Fax: 0781/203-1174
Whenever any electrical components are disconnected and
reconnected, replaced or repaired, a safety test must be
conducted, at least on these components!!!
), rinse water temperatures (
x2
x3
for demineralised water or
x5
gültig ab: 2003-01

W e reserve the right to change execution and construction!

At least once
Cleaning works
Daily
) and
Ident-Nr.: 9619165
Update: 2004-05-07
Service step
At least once
quarterly
or twice a
year
but
every
1000 h
At least once
yearly
but
every
2000 h