Service Instructions Dishwashing Machine Model K-Tronic
ATTENTION!
ATTENTION!
Datei: 2K_9628652_Serviceanleitung-MIKE_EN_2005-09-01.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174
Use safety glasses or goggles!
Always wear safety glasses or goggles when working on the dosing system.
WE ACCEPT NO LIABILITY FOR DAMAGE OR
INJURY ARISING FROM FAILURE TO OBSERVE
AND ABIDE BY THESE SAFETY INSTRUCTIONS.
2.2.1

Working on electrical equipment

Any repair work and repairs to the power supply on the installation's electrical equipment
may only be carried out by a qualified electrician trained and authorized by MEIKO.
Check the electrical equipment regularly!
Tighten any loose connections!
Replace any damaged leads/cables immediately!
Always keep the switch cabinets locked! Access is only allowed to qualified persons.

2.3 Connection to the electricity supply

Work on the electrical part of the machine may only be undertaken by specialist
personnel.
The wiring diagram is located in the switch cabinet. This wiring diagram is part of the
machine and therefore must not be removed.
The manufacturer's plate with the connected electrical loads is located inside the switch
cabinet.
General Electrical Regulations must be observed when connecting the machine to the
power supply.
Attention:
The fuses on site must be selected to suit the local conditions and
the appliance's nominal current in such a way that back-up
protection is guaranteed (Germany: VDE 0100).
The mains supply cables must be provided with fuses in accordance
with regulations and must have a main switch (accessible on site or
inside the appliance for operating personnel). If the neutral conductor
(N) is not grounded, a 4 phase main switch must be used. Cables
connecting to the main power supply must be oil-resistant and
sheathed and must not be lighter than an H 07 RN-F cable.
The potential equalisation connection must be carried out in
accordance with the
company and all applicable local regulations (in Germany VDE 0100
Part 540 must be observed).
Where VDE 0160 / EN 50178 applies, there is a requirement that in
areas of electrical equipment where line-side residual current
protective circuit breakers (FI) are planned or installed, an FI type B
device sensitive to all types of currents must be installed before the
FI type A.
For the supply connection use a 5-pole terminal strip (L1, L2, L3, N,
PE).
valid from: 2005-09-01

W e reserve the right to change execution and construction!

requirements of the local electricity supply
Update: 2006-11-14 / S.5
Ident No.: 9627429
Page 6/30