Fresh Water Connection; Waste Water Connection - Meiko K-Tronic Service Manual

Basket transport dishwashing machine

Advertisement

Operating instructions dishwashing machine model K-Tronic
Datei:2K_9626212_Betriebsanleitung-MIKE_EN_2005-12-01.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: 0781/203-0, Fax: 0781/203-1174
5.8

Fresh water connection

The water-carrying pipes and components are not frost-proof.
If the temperature of the place where the appliance has been installed can fall below 5°C,
suitable precautions for protection against frost must be taken.
Information on nominal widths, cross sections etc. relate to the appliance.
Installations on site must be dimensioned to match local conditions (e. g. cable
arrangements, access lengths).
The terminal positions of media and energy connections to the machine depend on the
method of construction (normally at a distance from the connection points on site). The
connections must be made by approved technicians.
All parameters for the media and energy supplies must be maintained at a constant level
during all the operations.
Fresh water connections must be carried out in accordance with the requirements of the
local regulations (e.g. Germany DIN 1988). A stop tap must be installed in all ingoing
water supply pipes and must be accessible to operating personnel. A tap capable of
isolating the appliance from the mains (in Germany in accordance with EN1717) installed.
Fresh water connections must be carried out in accordance with the requirements of the
local regulations (e.g. Germany DIN 1988).
Information on the water quantities, quality and temperatures needed can be found in the
installation plan.
The water quality must also comply with the requirements of the Commercial Dish-
Washing Association. (http:// www.vgg-online.de).
Most appliances are equipped with heat regeneration or with a heat pump.
In order for this equipment to operate at optimum efficiency the inlet temperature of the
rinse water supply must be maintained at a low a level as possible (ideally about 10°C).
Water supply at a higher temperature not only detracts from the efficiency of the heat
regeneration and the heat pump, but also impairs conditions relating to the appliance's
exhaust air.
If valves on the appliance are also controlled by fresh water, a minimum flow pressure is
necessary. See "Regulations and Standard Values" for the necessary pressures and
quantities.
5.9

Waste water connection

The waste water connection must be carried out in accordance with the requirements of
DIN 1986 and all applicable local regulations.
gültig ab: 2003-01
W e reserve the right to change execution and construction!
It is possible to clean the dirt screens without turning off the
main water supply.
The water supply is automatically cut off when the lower
component in which the screen is located is unscrewed.
This enables the screen can be easily cleaned during
maintenance.
(This cut-off function can also be used as a stop-cock when
servicing the machine.)