Service Instructions Dishwashing Machine Model K-Tronic
I1:0 23
AI:165 145 143 156°F
O1: 1 34
Datei: 2K_9628652_Serviceanleitung-MIKE_EN_2005-09-01.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174
It is helpful to obtain detailed information without having to look elsewhere when
servicing and commissioning machines (e.g. connect notebook).
If the information display is not in current use, status information on the inputs/outputs
from the individual I/O circuit boards can be called up at the same time as the process
(but not when in parameterising mode) provided that the function is available (see
service level parameter P128).
By pressing the arrow key
current status information on the inputs/outputs can be called up as described in the
examples below. Each touch of the key moves you onto the next or the previous
available input/output circuit board address. The I/O status display is ended by pressing
the
key on reaching the last address or pressing the
address. If no arrow key is pressed for a specific period (4 minutes), the input/output
status output is automatically left.
If the option "display input / output status" has been activated, the LCD display appears
as follows (time, date, etc is therefore removed and only the information from an input /
output component can be displayed. The selection function is available):
7 9 1
Operation
7
01
st
The 1
line shows the status of the following inputs (activated display of the number
means that current can flow (status 1)):
From the left:
0, 1, 2, ..., 7
8, 9, 0, 1 Condition of the conductivity inputs/digital inputs as in the
circuit diagram (only for I/O1 circuit board)
(the above example indicates that I1.0, I1.2, I1.3, I1.7, I1.9, I1.11
are active)
The outputs are arranged as follows in line 4 (activated display of the number means
that the corresponding output has just been switched on):
From the left: O1: 0, 1, 2, ..., 9, 0, 1 outputs 0 .. 11 as in the circuit diagram
(the above example indicates that O1.1, O1.3, O1.4, O1.7, O1.10, O1.11 are active)
The temperatures of the sensors connected to the corresponding I/O circuit board are
shown in line 3:
From left: Temperature 1
Temperature 2
Temperature 3 (only I/O3 circuit board)
Temperature 4 (only I/O3 circuit board)
valid from: 2005-09-01

W e reserve the right to change execution and construction!

or
(depending on the process status of the appliance)
I1:0 23
AI: 65
O1: 1 34
Digital inputs as in the circuit diagram
Update: 2006-11-14 / S.5
key on reaching the first
7 9 1
Operation
85
43
75°C
7
01
Page 12/30