Download Print this page

W E Reserve The Right To Change Execution And Construction - Meiko K-Tronic Service Manual

Basket transport dishwashing machine

Advertisement

Service Instructions Dishwashing Machine Model K-Tronic
Datei: 2K_9628652_Serviceanleitung-MIKE_EN_2005-09-01.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174
Temp.3rd line on/off
109
Temp.4th line on/off
110
Temperature 1st line
125
Temperature 3rd line
126
127
Temperature 4th line
I/O display active
128
201
Registr.refill ccles
202
Error behaviour
Starting condition
203
valid from: 2005-09-01

W e reserve the right to change execution and construction!

Program Selection button after
reaching ready for operation
Display temperature according to
P126 (3
0: no
1: Filling/heating
2: Ready for operation
3: Operation
4: always (1, 2 and 3)
Display temperature according to
P125 or P127 (1
0: no
1: Filling/heating
2: Ready for operation
3: Operation
4: always (1, 2 and 3)
Definition temperatures to be
displayed per line
Determination (2 temp. per line
possible):
0: no display
1: Temp. PW
2: Temp. WT7
..
8: Temp. WT1
9: Temp. PAR
10: Temp. FR
11: Temp. FR2
12: Temp. Drying
Example:
see P125
see P125
Enable I/O status:
0: no
1: yes
Log refilling cycles;
Activate monitoring ?
Individual determinations: (Bit 7 .......
Bit 0)
Bit 0: All pumps OFF and conveyor
Bit 1: All pumps OFF and conveyor
Bit 2: Conveyor stop in case of min.
Bit 3: Conveyor stop in case of min.
Bit 4: Conveyor stop in case of low
Bit 5:
Bit 6:
Bit 7:
-
Define the criteria (temperature) for
reaching "ready for operation":
0: set temperature of WT1
1: set temperature of PKSP
2: set temperature WT1 + P302
3: set temperature PKSP + P302
The actual temperature in WT1 and
Update: 2006-11-14 / S.5
rd
line) if:
st
th
or 4
line) if:
8
10
WT1
FR
OFF if pump error
OFF if fan error
temp. WT
temp FR1/2
flow in FR
Page 17/30
Ident No.: 9627429

Hide quick links:

Advertisement

Chapters

loading