Download Print this page

W E Reserve The Right To Change Execution And Construction - Meiko K-Tronic Service Manual

Basket transport dishwashing machine

Advertisement

Operating instructions dishwashing machine model K-Tronic
Maintenance
VERY IMPORTANT:
17. Visual check on the machine environment
Foaming detergents must not be used close to the machine area and not in
connection with the machine
Water treatment installation (if present)
Reverse osmosis installation (visual check); inform customers on the
necessity of installation maintenance
Demineralisation installation (visual check); inform customers on the
necessity of installation maintenance
Observe the manufacturer's operating instructions in all cases
Air gap according to WRC (if present, i.e. for England)
Check the spray pattern for the perlator nozzle (on the water discharge)
Clean / descale the perlator nozzle (on the water discharge)
Maximum suction temperature fan 0 550 056
x1
Maximum suction temperature fan 0 550 050
Pump pre-cleaning temperature
x2
Detergent circulation tank temperature
Clean water rinse temperature
x3
Dryin temperature
x4
Minimum water quality according to the VGG
x5
Total salt content:
The service steps Servicestufen
trained operating personnel
company tradesman after instruction
trained company tradesmen or installation engineers
installation engineers trained by MEIKO
You can document the completed maintenance work on the following pages. Meiko recommends that you enter the
half-yearly service steps (
Datei:2K_9626212_Betriebsanleitung-MIKE_EN_2005-12-01.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: 0781/203-0, Fax: 0781/203-1174
Whenever any electrical components are disconnected and
reconnected, replaced or repaired, a safety test must be
conducted, at least on these components!!!
according to DIN 10510
according to DIN 10510
according to DIN 10510
according to DIN 10510
max. 400
S/cm for porcelain and opal glass
max. 100
S/cm for glass
max. 80
S/cm for stainless steel (cutlery)
-
must be carried out by personnel trained for this purpose.
), and the annual service steps (
gültig ab: 2003-01

W e reserve the right to change execution and construction!

Service step
At least once
Cleaning works
quarterly
Daily
75°C
75°C
40°C to 50°C
55°C to 65°C
80°C to 85°C
not specified (see x
).
Ident-Nr.: 9619165
Update: 2004-05-07
At least once
At least once
or twice a
yearly
year
but
but
every
every
2000 h
1000 h
)
1