7.3.9

Drying (BD)

Text in LCD display
Set temperature
Calibration sensor
7.3.10

Heat pump (HP)

Text in LCD display
Deactivate heat pump
7.3.11

Transport (TRSP)

Text in LCD display
Impulse switch mode
Imps. till trsp.stop
Imps. till KV start
Impulses duration KV
Imps. till PW start
Impulses duration PW
Imps.till WT7 start
Impulses duration WT7
......
Imps. till WT1 start
Impulses duration WT1
Imps. till PAR start
Impulses duration PAR
Imps. till FR start
Impulses duration FR
Imps. till FR2 start
Impulses duration FR2
Imps.till BD start
Impulses duration BD
Conv on after delay
valid from: 2005-09-01

W e reserve the right to change execution and construction!

Unit
° C
Definition for controller and monitoring;
K
Adjustment option
Instead of the heat pump functionality
(compressor, fan, pump), additional heating is
now activated in the FR (heating 3 parallel
with heating 1) and the heating regulation
enabled by WT1 (was not activated at all, or
only activated to a limited extent, see cold
water filling)
Activate system units depending on present
crockery (in wash operation)?
0: NO
1: Impulse switching only for PAR and FRx
(Clean water conservation unit)
2: Impulse switching without transport stop
(impulse switching for all systems except
transport)
3: Impulse switching with transport stop
(impulse switching for all systems)
Effect only on transport controls
(if impulse switch mode=3)
Evaluate shift register (KV)
After-run extension KV
Evaluate shift register (PW)
After-run extension PW
Evaluate shift register (WT7)
After-run extension WT7
......
Evaluate shift register (WT1)
After-run extension WT1
Evaluate shift register (PAR)
After-run extension PAR
Setup shift register (FR)
After-run extension FR
Evaluate shift register
After-run extension FR2
Evaluate shift register (BD)
After-run extension BD
The conveyor is switched on again with a time
delay after the conveyor switch is released.
Update: 2006-11-14 / S.5
Description
Description
Description
Page 20/30