Electrical connection

Work on the electrical part of the machine may only be undertaken by specialist
personnel.
The wiring diagram is located in the switch cabinet. This wiring diagram is part of the
machine and therefore must not be removed.
The manufacturer's plate with the connected electrical loads is located inside the switch
cabinet.
General Electrical Regulations must be observed when connecting the machine to the
power supply.
Attention:
The fuses on site must be selected to suit the local conditions and the
appliance's nominal current in such a way that back-up protection is
guaranteed (Germany: VDE 0100).
The mains supply cables must be provided with fuses in accordance
with regulations and must have a main switch (accessible on site or
inside the appliance for operating personnel). If the neutral conductor
(N) is not grounded, a 4 phase main switch must be used. Cables
connecting to the main power supply must be oil-resistant and
sheathed and must not be lighter than an H 07 RN-F cable.
The potential equalisation connection must be carried out in
accordance with the
company and all applicable local regulations (in Germany VDE 0100
Part 540 must be observed).
Where VDE 0160 / EN 50178 applies, there is a requirement that in
areas of electrical equipment where line-side residual current
protective circuit breakers (FI) are planned or installed, an FI type B
device sensitive to all types of currents must be installed before the FI
type A.
For the supply connection use a 5-pole terminal strip (L1, L2, L3, N,
PE).
The electrical connection data, voltage, type of current, output can be seen on the
manufacturers' plates on the machine.
Please check the voltage.
All electrical connections must be made inside the electrical switch cabinet by means of
marked screwed cable glands as in the circuit diagram and connected to the terminals
and the fuses provided.