Information output
Next maintenance in
Total Operation time
Running time
Wash pumps
Running time
Drying fan
Number of baskets
FR water consumption
FR water flow
FR2 water consump.
FR2 water flow
Water consumption
filling valve
Temperature PW
Temperature WT6
Temperature WT5
Temperature WT4
Temperature WT3
Temperature WT2
Temperature WT1
Temperature PAR
Temperature FR
Temperature FR2
Temperature Drying
Serial number
Order number
Heat pump
deactivated
or
Defrosting
in operation
or
Power regulation in
operation
Or
Defrosting / Power
regulation in operation
or
Hot gas by-pass OFF
6.3

I/O Status OUTPUT

When the machine is in the operating conditions Machine Off, Fill/Heat, Ready for
Operation, Operating and Pumping out, it is possible (option) to obtain information on
the status of digital inputs and outputs and the temperatures of an I/O module in the 1
rd
th
nd
3
and 4
lines (the 2
valid from: 2005-09-01

W e reserve the right to change execution and construction!

Operating hours till next maintenance
Counting up in the operating conditions
Filling/Heating/Ready for op./Operation
Counting up while WP ON;
Applies as reference for maintenance!
Counting up while fan ON;
If basket counter available;
Display with one decimal place
Current actual value
Display with 1 decimal place
(Only if available)
Current actual value
(Only if available)
Only if water meter available (see separate
parameter)
Actual temperature prewash tank (PW)
(Only if available)
Actual temperature wash tank 6 (WT6)
(Only if available)
Actual temperature wash tank 5 (WT5)
(Only if available)
Actual temperature wash tank 4 (WT4)
(Only if available)
Actual temperature wash tank 3 (WT3)
(Only if available)
Actual temperature wash tank 2 (WT2)
(Only if available)
Actual temperature wash tank 1 (WT1)
(Only if available)
Actual temperature pump final rinse (PAR)
(Only if available)
Actual temperature final rinse 1 (FR)
Actual temperature final rinse 2 (FR2)
(Only if available)
Actual temperature drying
(Only if available)
Option for calling up works parameters
Option for calling up works parameters
Only if a heat pump is available
Output depending on the status of the entries low
pressure switch
defrosting or high pressure switch
power regulation
column continues to display the operating condition).