4.

DISASSEMBLY AND INSTALLATION

4.1

Covers

[A] Stationary tray
(1)
Open the stationary tray.
(2)
Loosen 2 screws each from the front and
back side tray, and remove 2 right side
screws.
(3)
Lift the stationary tray upward to take off
while pulling the jam access lever.
Notes:
Be sure to install or remove the stationary
tray with the stationary tray being opened,
otherwise the upper exit roller guide may
be damaged.
Be sure not to damage the actuator of the
stationary tray paper-full sensor.
Notes:
Be sure not to lose 4 pins of the buffer
unit-1.
Before installing the stationary tray, adjust
the installing positions of the 4 pins of the
buffer unit-1 to the center position.
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Actuator
Stationary
tray
Fig. 4-1
Pin
Fig. 4-2
4 - 1
Jam access lever
Buffer unit-1
MJ-1103/1104