(3)
Remove 2 screws, and then take off the sen-
sor rail.
Note:
When installing the movable tray drive unit,
fix it at the position where the gap between
the center mark of the scale on the sensor
rail and the edge of the movable tray posi-
tion-a sensor is from 0 to 1 mm. Be sure to
adjust the installation position by shifting the
movable tray shift frame and measure the
positions at the upper and lower measuring
points on the sensor rail as shown in the fig-
ure.
(4)
Release the latch, and then disconnect the
connectors to take off the movable tray posi-
tion-a sensor, movable tray position-B sen-
sor and movable tray position-c sensor.
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Fig. 4-284
Sensor rail
Sensor
Measure
0mm to 1.0mm
Fig. 4-285
Movable tray
position-A sensor
Movable tray
position-B sensor
Movable tray
position-C sensor
Fig. 4-286
4 - 101
Sensor rail
MJ-1103/1104