PROBLEM
Scan does not operate.
• The squelch s open.
• Only 1 memory channel s programmed or other
channels are set as skp channels.
• Prorty watch s actvated.
The functon dsplay shows
• The CPU s malfunctonng.
erroneous nformaton.
D a t a c o m m u n c a t o n
• Ethernet cable has a poor connecton.
cannot be made properly
■ Fuse replacement
If the fuse blows or the transcever stops functonng, find the
source of the problem f possble, and replace the damaged
fuse wth a new, rated one (FGB 15 A) as shown at rght.
The DC power cable has 2 fuses, one each for postve (+;
red) and negatve (–; black) lne.
POSSIBLE CAUSE
SOLUTION
• Set the squelch to the threshold pont.
• Program other memory channels or cancel the
memory skp functon n the desred channels.
• Cancel the watch.
• Reset the CPU.
• Re-connect the Ethernet cable.
• Replace the Ethernet cable.
15 A
fuse
15
MAINTENANCE
REF.
p. 33
pgs. 74
to 76
pgs. 90,
91
p. 112
p. 17
15
114