Netware; Netware Failure Scenarios - HP StorageWorks 6100 - Enterprise Virtual Array User Manual

Hp storageworks 4x00/6x00/8x00 enterprise virtual array user guide (5697-8037, april 2009)
Hide thumbs Also See for StorageWorks 6100 - Enterprise Virtual Array:
Table of Contents

Advertisement

Fault stimulus
Server path failure
Storage path failure

NetWare

Table 60 NetWare failure scenarios.
Fault stimulus
Server failure (host power-cycled)
Switch failure (SAN switch disabled)
Controller failure
Controller restart
Server path failure
Storage path failure
204
Single Path Implementation
Failure effect
OpenVMS—OS will report the volume in a Mount Verify state until
the MVTIMEOUT limit is exceeded, when it then marks the volume
as Mount Verify Timeout. No data is lost or corrupted.
Tru64 UNIX—All I/O operations halted. I/O errors are returned
back to the applications. An I/O failure to the system disk can cause
the system to panic. Possible data loss from unfinished or unflushed
writes. File system check may be needed upon reboot.
OpenVMS—OS will report the volume in a Mount Verify state until
the MVTIMEOUT limit is exceeded, when it then marks the volume
as Mount Verify Timeout. No data is lost or corrupted.
Tru64 UNIX—I/O fails over to the surviving path. No data is lost
or corrupted.
Failure effect
OS reboots. When mounting volumes, volume repair or NSS rebuild
executes to cleanup volumes. Data loss, data that finished writing
survived.
I/O to device stops with I/O errors indicated on server console.
Applications using lost connection halts. Server restart recommended
but may not be necessary. Volume repair or NSS rebuild runs when
volumes are mounted.
I/O to device stops with I/O errors indicated on server console.
Applications using lost connection halts. Server restart recommended
but may not be necessary. Volume repair or NSS rebuild runs when
volumes are mounted.
I/O to device stops with I/O errors indicated on server console.
Applications using lost connection halts. Server restart recommended
but may not be necessary. Volume repair or NSS rebuild runs when
volumes are mounted.
I/O to device stops with I/O errors indicated on server console.
Applications using lost connection halts. Server restart recommended
but may not be necessary. Volume repair or NSS rebuild runs when
volumes are mounted.
I/O to device stops with I/O errors indicated on server console.
Applications using lost connection halts. Server restart recommended
but may not be necessary. Volume repair or NSS rebuild runs when
volumes are mounted.