Failback Settings By Operating System - HP StorageWorks 6100 - Enterprise Virtual Array User Manual

Hp storageworks 4x00/6x00/8x00 enterprise virtual array user guide (5697-8037, april 2009)
Hide thumbs Also See for StorageWorks 6100 - Enterprise Virtual Array:
Table of Contents

Advertisement

Setting
Point in time
On dual boot or controller resynch
On controller failover
On controller failback
At initial presentation
On dual boot or controller resynch
Path B - Failover/Fail-
On controller failover
back
On controller failback
Table 4
describes the failback default behavior and supported settings when Secure Path is running
with each operating system or when MPIO 2.x or 3.x is running with Windows.
Table 4 Failback Settings by operating system
Operating system
1
HP-UX
Tru64 UNIX
OpenVMS (7.3-1 and
greater)
2
Windows
Sun Solaris
IBM AIX
Linux
HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array user guide
Default behavior
See
Table
3.
Host follows the unit
Host follows the unit
Host follows the unit
See
Table
3.
See
Table
3.
See
Table
3.
Behavior
If cache data for a LUN exists on a partic-
ular controller, the unit will be brought
online there. Otherwise, the units are
brought online to Controller A.
All LUNs are brought online to the surviv-
ing controller.
All LUNs remain on the surviving control-
ler. After controller restoration, the units
that are online to Controller B and set to
Path A are brought online to Controller A.
This is a one time occurrence. If the host
then moves the LUN using SCSI com-
mands, the LUN will remain where moved.
The units are brought online to Controller
B.
If cache data for a LUN exists on a partic-
ular controller, the unit will be brought
online there. Otherwise, the units are
brought online to Controller B.
All LUNs are brought online to the surviv-
ing controller.
All LUNs remain on the surviving control-
ler. After controller restoration, the units
that are online to Controller A and set to
Path B are brought online to Controller B.
This is a one time occurrence. If the host
then moves the LUN using SCSI com-
mands, the LUN will remain where moved.
Settings supported
No Preference, Path A/B – Failover Only.
All settings allowed. Recommended setting: Path
A/B – Failover/Failback.
All settings allowed. Recommended setting: Path
A/B – Failover/Failback.
All settings allowed. Recommended setting: Path
A/B – Failover/Failback.
No Preference, Path A/B – Failover Only.
No Preference, Path A/B – Failover Only.
No Preference, Path A/B – Failover Only.