1.3.en.01 NONCRITICAL condition—High current
This condition report indicates that an element current is approaching, but has not reached, the high
current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL
condition. This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP-authorized
service representative.
1.3.en.02 CRITICAL condition—High current
This condition report indicates that an element current has reached the high current CRITICAL threshold.
This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP-authorized
service representative.
Backplane conditions
IMPORTANT:
Backplane
NVRAM errors usually occur during manufacture. At this time they are identified and
corrected. They rarely occur during normal operation.
The format of a
•
8.2. is the
01. is the two-character
•
•
ec is the error code
The only corrective action available for this error is to replace the drive enclosure.
8.2.01.10 NONCRITICAL condition—Backplane NVRAM read
An invalid NVRAM read occurred and an automatic recovery process has begun. This condition
report is active for 15 seconds.
If the automatic recovery process does not correct the problem, record all six characters of the condition
report, then contact your HP-authorized service representative.
8.2.01.11 NONCRITICAL condition—Backplane NVRAM write failure
The system is unable to write data to the NVRAM. This problem prevents communication between
elements in the enclosure. This condition report is active for 15 seconds.
To correct this problem, record all six characters of the condition report, then contact your HP-authorized
service representative.
8.2.01.12 NONCRITICAL condition—Backplane NVRAM read failure
The system is unable to read data from the NVRAM. This problem prevents communication between
elements in the enclosure. This condition report is active for 15 seconds.
164
EMU-generated condition reports
condition report is 8.2.01.ec, where:
backplane
backplane
element type number
backplane
element number
Need help?
Do you have a question about the StorageWorks 6100 - Enterprise Virtual Array and is the answer not in the manual?