hub
A communications infrastructure device to which nodes on a multi-point bus or
loop are physically connected. It is used to improve the manageability of physical
cables.
I/O module
Input/Output module. The enclosure element that is the Fibre Channel drive
enclosure interface to the host or controller. I/O modules are bus speed specific,
either 1 Gb or 2 Gb.
IDX
A 2-digit decimal number portion of the HSV controller termination code display
that defines one of 32 locations in the Termination Code array that contains
information about a specific event.
See also
in-band
The method of communication between the EMU and controller that utilizes the
communication
Fibre Channel drive enclosure bus.
INFORMATION
A drive enclosure EMU condition report that may require action. This condition
condition
is for information only and does not indicate the failure of an element. All
condition reports have precedence over an INFORMATION condition.
initialization
A process that prepares a storage system for use. Specifically, the system binds
controllers together as an operational pair and establishes preliminary data
structures on the disk array. Initialization also sets up the first disk group, called
the default disk group.
input/output
See
module
intake temperature
See
interface
A set of protocols used between components such as cables, connectors, and
signal levels.
JBOD
Just a Bunch of Disks. A number of disks connected to one or more controllers.
K
Kilo. A scientific notation denoting a multiplier of one thousand (1,000).
KB
Kilobyte. A unit of measurement defining either storage or memory capacity.
1.
2.
LAN
Local area network. A group of computers and associated devices that share a
common communications line and typically share the resources of a single
processor or server within a small geographic area.
laser
A device that amplifies light waves and concentrates them in a narrow, very
intense beam.
Last Fault View
An HSV Controller display defining the last reported fault condition.
Last Termination
See LTEA.
Error Array
LCD
Liquid Crystal Display. The indicator on a panel that is associated with an element.
The LCD is usually located on the front of an element.